Handrails and guards must be designed to resist a linear load of 50 pounds per linear foot and a concentrated load of 200 pounds. Intermediate rails, balusters, and panel fillers must resist a concentrated load of 50 pounds.

According to Section 1607.8.1 of the 2018 International Building Code, handrails and guards should be designed to withstand a linear load of 50 pounds per linear foot. Additionally, they must be capable of resisting a concentrated load of 200 pounds. For intermediate rails, balusters, and panel fillers, the design must accommodate a concentrated load of 50 pounds. These specifications ensure that the structures can handle the expected forces and provide safety and stability.

Key points

  • Handrails and guards: 50 pounds per linear foot linear load.
  • Handrails and guards: 200 pounds concentrated load.
  • Intermediate rails, balusters, panel fillers: 50 pounds concentrated load.
  • Design ensures safety and stability against expected forces.