EbookQA
ProcessAdvanced

How should gypsum board be applied to achieve the required fire-resistance rating for structural steel columns according to the 2018 International Building Code?

To achieve the required fire-resistance rating for structural steel columns using gypsum board, apply Type X gypsum wallboard vertically without horizontal joints or with staggered joints. The total thickness of the gypsum board depends on the fire-resistance rating and the weight-to-heated-perimeter ratio (W/D) of the column.

To ensure the required fire-resistance rating for structural steel columns, Type X gypsum wallboard should be applied vertically to the column. This can be done in a single layer without horizontal joints or in multiple layers with staggered horizontal joints. The joints should be staggered by at least 12 inches vertically between layers and not less than 8 feet vertically in any single layer. The total thickness of the gypsum board is determined based on the specified fire-resistance rating and the weight-to-heated-perimeter ratio (W/D) of the column. For fire-resistance ratings of 2 hours or less, one layer of gypsum board may be applied to the exterior of sheet steel column covers, with specific attachment requirements for screws and corner beads.

Key points

  • Use Type X gypsum wallboard for protection.
  • Apply gypsum board vertically to columns.
  • Single or multiple layers can be used, with staggered joints if multiple.
  • Thickness depends on fire-resistance rating and W/D ratio.
  • For 2-hour ratings, one layer may be applied externally with specific screw and bead requirements.
Source:2018 international building code by international code council· Building Systems· p. 208–222

Related questions

Cover of 2018 international building code by international code council

2018 international building code by international code council

Unknown

First Printing · INTERNATIONAL CODE COUNCIL, INC.

View this ebook