How should fire barriers extend according to Section 707.5 of the 2018 International Building Code?

Fire barriers must extend from the top of the foundation or floor/ceiling assembly below to the underside of the floor or roof sheathing, slab, or deck above. They must be securely attached and continuous through concealed spaces, such as above suspended ceilings.

According to Section 707.5 of the 2018 International Building Code, fire barriers are required to extend from the top of the foundation or the floor/ceiling assembly below to the underside of the floor or roof sheathing, slab, or deck above. This ensures that the fire barrier is continuous and securely attached, providing effective fire separation. Additionally, fire barriers must continue through concealed spaces, such as the space above a suspended ceiling, to maintain their integrity and effectiveness in preventing the spread of fire.

Key points

  • Fire barriers extend from foundation or floor/ceiling below to underside of floor or roof above.
  • They must be securely attached to the structure.
  • Continuity through concealed spaces, like above suspended ceilings, is required.
  • Ensures effective fire separation and containment.
Source:2018 international building code by international code council· Specific Requirements to Allow Use and Access to a Building for Persons with Disabilities· p. 159–161